{"product_id":"edwards-xds100b-scroll-pump-1-ph-100-120-200-230v-set-to-230v-a73201983","title":"Edwards XDS100B Scroll Pump 1-ph, 100-120\/200-230V Set to 230V A73201983","description":"\u003cp\u003eEdwards XDS100B Scroll Pump 1-ph, 100-120\/200-230V Set to 230V A73201983 \u003c\/p\u003e\n\u003cp\u003eThe XDS100B is a scroll booster, with a pumping mechanism design specifically for high pumping speed. Like all booster pumps, it needs to be used in conjunction with a primary pump and is ideally matched with Edwards XDS35i or XDS46i scroll pumps. The XDS100B is optimized for maximum pumping speed at inlet pressures between 1 mbar and 10 mbar making in virtually no tip seal wear thus reducing service intervention and maximizing uptime. The inverter drive allows the pump to be connected to a single phase supply and controls the motor characteristics and ensures the pump always run at optimum speed and allows the user to control the pump remotely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLubricant-free within the vacuum envelope and hermetically sealed means totally clean and dry vacuum to prevent cross contamination\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNo atmosphere to vacuum shaft seals means bearings are completely isolated, this prevents process attack and means bearings run cooler and last longer\u003c\/li\u003e\n\u003cli\u003eNo oil changes required eliminating costs of contaminated oil disposal\u003c\/li\u003e\n\u003cli\u003eSimple single sided scroll design means maintenance is done in minutes for low cost of ownership and maximum up-time\u003c\/li\u003e\n\u003cli\u003eInverter drive for consistent pumping speed at 50\/60Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh throughput -LCMS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"619\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"417\"\u003ePumping speed\u003c\/td\u003e\n\u003ctd width=\"202\"\u003e50 or 60Hz 95 m\u003csup\u003e3\u003c\/sup\u003eh\u003csup\u003e-1\u003c\/sup\u003e \/ 56 ft\u003csup\u003e3\u003c\/sup\u003emin\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltimate vacuum (Total pressure)*\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1 x 10\u003csup\u003e-2\u003c\/sup\u003e mbar \/ \u0026lt;8 x 10\u003csup\u003e-3\u003c\/sup\u003e Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax continuous inlet pressure\u003c\/td\u003e\n\u003ctd\u003e20 mbar \/ 15 Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax permitted continuous exhaust pressure\u003c\/td\u003e\n\u003ctd\u003e60 mbar \/ 45 Torr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax permitted inlet pressure for short duration\u003c\/td\u003e\n\u003ctd\u003e0.5 bar gauge \/ 7 psig\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax chamber volume to pump down from Atmospheric pressure\u003c\/td\u003e\n\u003ctd\u003e100 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax chamber volume for cyclic duty -max 6 per hour\u003c\/td\u003e\n\u003ctd\u003e50 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power\u003c\/td\u003e\n\u003ctd\u003e0.52kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Connector\u003c\/td\u003e\n\u003ctd\u003eIEC EN60320 C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal rotation speed\u003c\/td\u003e\n\u003ctd\u003e1750 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e48 kg \/ 105 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet flange\u003c\/td\u003e\n\u003ctd\u003eNW40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExhaust flange\u003c\/td\u003e\n\u003ctd\u003eNW40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise level\u003c\/td\u003e\n\u003ctd\u003e52.1 dB (A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;4.5mms \u003csup\u003e-1 \u003c\/sup\u003e(rms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeak tightness (static)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1 x 10\u003csup\u003e-6 \u003c\/sup\u003embar ls\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature range\u003c\/td\u003e\n\u003ctd\u003e10 to 40 °C \/ 50 to 104 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e* Ultimate pressure is backing pump dependant\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":1187853456,"sku":"A73201983","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/2467\/products\/edwards-xds100b-scroll-pump-1-ph-100-120-200-230v-set-to-230v-a73201983-17333354592.jpg?v=1779797083","url":"https:\/\/www.chemtechsci.com\/products\/edwards-xds100b-scroll-pump-1-ph-100-120-200-230v-set-to-230v-a73201983","provider":"Chemtech Scientific Incorporated","version":"1.0","type":"link"}